6-14 The Keypad
DC590+ DRV Series DC Digital Drive
DIAGNOSTICS (MMI only)
Parameter Tag Range SETUP PARAMETERS Function Blocks
RAISE/LOWER O/P 264
.xx %
Value of the raise/lower ramp function. Refer to RAISE/LOWER
PID OUTPUT 417
.xx %
Output of the PID function block. Refer to PID
PID CLAMPED 416 FALSE / TRUE
Indicates the PID output has reached either the positive or negative limit. Refer to PID
PID ERROR 415
.xx %
Displays the difference between the setpoint (INPUT 1) and the feedback signal (INPUT
2) in the PID function block.
Refer to PID
SPT SUM OUTPUT 86
.xx %
Setpoint summation output. Refer to SETPOINT SUM 1
RAMP OUTPUT 85
.xx %
Setpoint ramp output. Refer to RAMPS
PRESET O/P 572
.x %
Scales the selected preset input by MAX SPEED. Refer to PRESET SPEEDS
SRAMP OUTPUT 589
.x %
Diagnostic, ramp output. Refer to SRAMP
OUTPUT FPM 593
.x
Outputs the selected INPUT value. Refer to PRESET SPEEDS
SPEED SETPOINT 63
.xx %
Speed loop total setpoint including the ramp output before the ramp-to-zero function. Refer to SPEED LOOP
TERMINAL VOLTS 57
.x %
Scaled armature terminal volts. Refer to CALIBRATION
BACK EMF 60
.x %
Calculated motor back EMF including IR. compensation. (Armature Volts Feedback) Refer to CALIBRATION
ARM VOLTS FBK 605
. V
Back EMF scaled by NOM MOTOR VOLTS (CONFIGURE DRIVE function block). Refer to FEEDBACKS
TACH INPUT 308
.x %
Scaled analog tachogenerator feedback. Refer to FEEDBACKS

Table of Contents