3-6 Installing the Drive
DC590+ DRV Series DC Digital Drive
EMC Wiring Details
Cabling Requirements
Cables are considered to be electrically sensitive, clean or noisy. You should already have planned your cable routes with respect to segregating these
cables for EMC compliance. If not, refer to Appendix B: “Certification”.
If the drive is to be operating in a regenerating mode for extended periods acting as a load generator for another machine, it is advisable to fit
additional protection in the armature circuit. A dc fuse or high speed circuit breaker will provide this protection. If in doubt, contact Parker SSD
Drives.
fuse or suitable
circuit breaker
(RCD not
recommended)
choke
contactor
external
ac
filter
(optional)
motor
drive
590AC
Line Choke
Filter
CO468398
motor cable
power
supply
cable
(noisy)
(noisy)
(clean)
Not fitted to
Frame H units
(sensitive)
signal/control cable
field cable
Figure 3-1 Cabling Requirements