The Keypad
6-15
DC590+ DRV Series DC Digital Drive
DIAGNOSTICS (MMI only)
Parameter Tag Range SETUP PARAMETERS Function Blocks
UNFIL.TACH INPUT 58
.x %
Analog tachogenerator feedback (unfiltered). Refer to CALIBRATION
ENCODER 206
. RPM
Encoder speed feedback in RPM. Refer to ENCODER
UNFIL.ENCODER 59
. RPM
Encoder speed feedback in RPM (unfiltered). Refer to ENCODER
UNFIL.SPD.FBK 62
.xx %
Unfiltered speed feedback. Refer to SPEED LOOP
UNFIL.SPD.ERROR 64
.xx %
Unfiltered speed error. Refer to SPEED LOOP
CONTACTOR CLOSED 83 FALSE / TRUE
Main contactor control signal. Refer to SEQUENCING
HEALTH LED 122 FALSE / TRUE
State of Health LED on Keypad. Refer to ALARMS
READY 125 FALSE / TRUE
The drive is ready to accept an enable signal. Refer to SEQUENCING
DRIVE RUNNING 376 FALSE / TRUE
Drive is enabled and may make current when TRUE. A diagnostic for those parameters
that can only be written to when the drive is stopped (parameters marked with Note 2 in
the Parameter Specification Table).
Refer to SEQUENCING
SYSTEM RESET 374 FALSE / TRUE
Set for one cycle as the drive is enabled. Refer to SEQUENCING
SETUP PARAMETERS
Refer to Appendix D for parameter details. A parameter can be located by referring to the Parameter Specification Table: Tag Number Order.
The layout of this 590+ menu is shown by
The Menu System Map on page 6-8.