D-36 Programming
DC590+ DRV Series DC Digital Drive
CURRENT LOOP
Parameter Tag Range
POS. I CLAMP 87
⎯.x %
Refer to Chapter 6: "The Keypad" - The Keypad Menus (DIAGNOSTICS).
NEG. I CLAMP 88
⎯.x %
Refer to Chapter 6: "The Keypad" - The Keypad Menus (DIAGNOSTICS).
ACTUAL POS I LIM 67
⎯.x %
Refer to Chapter 6: "The Keypad" - The Keypad Menus (DIAGNOSTICS).
ACTUAL NEG I LIM 61
⎯.x %
Refer to Chapter 6: "The Keypad" - The Keypad Menus (DIAGNOSTICS).
ISOL DMD SOURCE 1275 ANIN 2 (A3) / FIELD I DEMAND
Selects the source of the isolated current demand.
¾ Setting ANIN 2 (A3) makes use of the A3 analogue input terminal as the current demand.
¾ Setting FIELD I DEMAND makes use of the current demand (%) at the field current controller, as the percentage armature current demand.
The use of this parameter is typically combined with parameters BEMF SOURCE, BEMF INPUT and 3-PHASE FIELD to apply the drive to field
weakening control of a motor field.