Programming D-91
DC590+ DRV Series DC Digital Drive
+
Input 1
[410]
Ratio 1
[412]
Divider 1
[418]
Input 2
[411]
Ratio 2
[413]
Divider 2
[414]
F
[403]
D
[401]
I
[402]
P
PID Output
[417]
+
+
+
+
Neg Limit
[406]
Pos limit
[405]
O/P Scaler
(Trim) [407]
PID Error
[415]
Enable
[408]
Integral Defeat
[409]
Reset
PID Clamped
[416]
0%
* - Linked internally to Diameter Calculator
Block Diagram
Prop Gain
[711]
+
+
Hi Res Prop Gain
[1259]
Operators can read the PID error, PID output, setpoint and feedback on the drive's MMI by monitoring the following values:
PID ERROR : displayed in the DIAGNOSTICS menu
PID OUTPUT : displayed in the DIAGNOSTICS menu
SETPOINT : monitored at SETUP PARAMETERS::SPECIAL BLOCKS::PID::INPUT 1