Programming D-135
DC590+ DRV Series DC Digital Drive
VALUE FUNCTION
Parameter Tag Range
INPUT A
830, 835, 840, 845, 850, 855, 860, 865, 870,
875
-32768 to 32768
General purpose input.
INPUT B
831, 836, 841, 846, 851, 856, 861, 866, 871,
876
-32768 to 32768
General purpose input.
INPUT C
832, 837, 842, 847, 852, 857, 862, 867, 872,
877
-32768 to 32768
General purpose input.
TYPE
833, 838, 843, 848, 853, 858, 863, 868, 873,
878
See below
The operation to be performed on the three inputs to produce the output value.
0: IF(C) -A
1: ABS(A+B+C)
2: SWITCH(A,B)
3: (A*B)/C
4: A+B+C
5: A-B-C
6: B<=A<=C
7: A>B+/-C
8: A>=B
9: ABS(A)>B+/-C
10: ABS(A)>=B
11: A(1+B)
12: IF(C) HOLD(A)
13: BINARY DECODE
14: ON DELAY
15: OFF DELAY
16: TIMER
17: MINIMUM PULSE
18: PULSE TRAIN
19: WINDOW
20: UP/DWN COUNTER
21: (A*B)/C ROUND
22: WINDOW NO HYST
23: WIND A>=B,A<=C
24: A<=B
25: ((A*B)/100)+C
26: MIN(A,B,C)
27: MAX(A,B,C)
28: PROFILE SQRT
29: PROFILE LINEAR
30: PROFILE x^2
31: PROFILE x^3
32: PROFILE x^4
33: ON A>B, OFF A<C
34: (A+B) CLAMPED C
35: (A-B) CLAMPED C
36: (A*B) CLAMPED C
37: (A/B) CLAMPED C
38: A>=B:A, A<=C:0
39: (A * B) + C
40: A * (B + C)
41: A * (B - C)
42: A * (1+B/C)
43: A * (1+(B * C))
44: MONOSTABLE HIGH
45: MONOSTABLE LOW
46: FILTER
OUTPUT
834, 839, 844, 849, 854, 859, 864, 869, 874,
879
⎯ .xx
The result of performing the selected operation on the inputs.