E-4 Technical Specifications
DC590+ DRV Series DC Digital Drive
3-Phase Power Supply Details
3-Phase Supply LV Build
All Frames
110-220V ± 10% ac, 50/60Hz ± 5%, line-to-line, earth/ground referenced (TN) and non-earth/ground referenced (IT)
Standard
All Frames
380-500V ± 10% ac, 50/60Hz ± 5%, line-to-line, earth/ground referenced (TN) and non-earth/ground referenced (IT)
HV Build
Frame 4
Frame 5
500-600V ± 10% ac, 50/60Hz ± 5%, line-to-line, ground referenced (TN) and non-ground referenced (IT)
HV Build Frame 6 & 7
380-690V ± 10% ac, 50/60Hz ± 5%, line-to-line, earth/ground referenced (TN) and non-earth/ground referenced (IT)
Supply Current (0.9 x ARMATURE CURRENT [IA CAL]) Amps ac rms
Field Supply Current (1 x FIELD CURRENT [IF CAL]) Amps ac rms (build related)
Field Supply Voltage Build-related
Phase 3-phase rotation insensitive, no adjustment necessary for frequency change
Control Power Supply Detail
Control Supply *
Auxiliary Supply Current
110-230V ±10%, 50-60Hz ±10%, single phase, Overvoltage Category II
“Where auxiliary cooling fans are used, then the supply is set by the requirement for the fan, i.e. 115V ±10% or 230V ±10%.”
Refer to the Model No. and Chapter 2: “An Overview of the Drive “ - Understanding the Product Code
3A ac rms maximum. Nominal current used for power supplies: 0.5A at 115V ac
Fan current for integral fans: refer to
Cooling Fans, page E-27. The remainder is available for driving the AC Contactor.
The control power is supplied by a built-in control transformer on Frame 3 and higher, providing an additional 100VA available for external control
equipment.
Contactor Output 3A maximum at the control voltage