Loading...
E-10 Technical Specifications
DC590+ DRV Series DC Digital Drive
Terminal Definitions (Digital/Analog Inputs & Outputs)
User inputs are IEC1131 compliant. Terminal blocks A, B, and C are located on the control board each block being a 9 way plug-in connector. In
addition to terminal blocks A, B and C, terminal blocks G and H provide connections when the two option modules are fitted on the control board.
Analog Output
Output Resolution
Output Drive Capacity
Update Interval
Settling Time
Output Overdrive Capability
Overload Protection
11 Bit plus sign, i.e. 5mV resolution, equals 0.05% of full scale deflection
10V at 5mA max.
5ms
5ms, for 0% to 90%
+10%, i.e. maximum output +/-11V at 2.5mA max.
Indefinite short circuit protection provided
Terminal Information - Power (Frames 1-5)
Note: On Frame 1 and 2 units, L1, L2, L3, A+ and A- terminals are located on a separate Terminal Board. On Frame 3, 4 & 5 units, they are
busbar connections.
Terminal Terminal Function Signal Level Customer Terminals
Description Frames 1, 2 Frames 3, 4, 5
Mains Supply L1 Three phase mains power input, phase reference Line 1 500Vac maximum 50-
60Hz
line-to-line
L1 L1
Mains Supply L2 Three phase mains power input, phase reference Line 2 500Vac maximum 50-
60Hz
line-to-line
L2 L2
Mains Supply L3 Three phase mains power input, phase reference Line 3 500Vac maximum 50-
60Hz
line-to-line
L3 L3
Armature
connection
positive
A+
Drive dc power output, reference Armature Positive connection to dc motor 550Vdc maximum with
respect to A- (maximum
voltage dependent upon
the supply voltage, the
ratio being: Vout is
approximately equal to
1.15Vac supply
A+ A+

Table of Contents