EasyManua.ls Logo

Parker 890CS - Page 25

Parker 890CS
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
890CS & 890CD Common Bus Units
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page 4-5
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
8
9
1
2
3
4
5
6
E
890 Operating Conditions
Humidity
Maximum 85% relative humidity at 40°C (104°F) non-condensing
Atmosphere Non flammable, non corrosive and dust free
Climatic Conditions Class 3k3, as defined by EN50178 (1998)
Vibration The product has been tested to the following specification:
Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Safety
Pollution Degree
Pollution Degree ll (non-conductive pollution, except for temporary
condensation)
Europe
When fitted inside an enclosure, this product conforms with the Low
Voltage Directive 73/23/EEC with amendment 93/68/EEC, Article 13
and Annex III using EN50178 (1998) to show compliance.
North America/ Canada
Complies with the requirements of UL508C as an open-type drive.

Table of Contents

Other manuals for Parker 890CS

Related product manuals