EasyManua.ls Logo

Parker 890CS - Page 387

Parker 890CS
586 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page D-43
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Parameter Descriptions
POSITION OUTPUT
PREF: 119.06 Default: —.xxxx deg Range: —.xxxx deg
This diagnostic shows the position demand in load mechanical degrees.
SPEED OUTPUT
PREF: 119.07 Default: —.xx Hz Range: —.xx Hz
This diagnostic shows the speed demand in load mechanical Hz (rev/s).
ACCEL OUTPUT
PREF: 119.08 Default: —.xx Range: —.xx
This diagnostic shows the acceleration demand in load mechanical Hz/s (rev/s
2
).
MASTER POSITION
PREF: 119.09 Default: —.xxxx deg Range: —.xxxx deg
This diagnostic shows the master aster position demand in mechanical degrees.
MASTER SPEED
PREF: 119.10 Default: —.xxxx Hz Range: —.xxxx Hz
This diagnostic shows the master speed demand in mechanical Hz (rev/s).
MASTER ACCEL
PREF: 119.11 Default: —.xxxx Range: —.xxxx
This diagnostic shows the master acceleration demand in mechanical Hz/s (rev/s
2
).
READY
PREF: 119.14 Default: FALSE Range: FALSE / TRUE
This diagnostic is TRUE when local drive is properly synchronised with the master, i.e. Status = READY.