Lubricating intervals and amount of lubricant for ATEX ETH- Electro Cylinder
192-550003N10 ETH ATEX December 2019 45
3.2 Lubricating intervals and amount of lubricant for ATEX
ETH- Electro Cylinder
Spindle
Interval
Amount of lubricant
ETH032
M05
80 km
1.3 cm
3
M10
160 km
1.6 cm
3
ETH050
M05
80 km
1.6 cm
3
M10
160 km
1.9 cm
3
ETH080
M05
80 km
3.1 cm
3
M10
160 km
4.4 cm
3
ETH100
M10
80 km
14 cm
3
M20
160 km
17 cm
3
ETH125
M10
60 km
20 cm
3
M20
120 km
48 cm
3
Lubricant
Do only use "Klüber NBU15" lubricating grease for standard
cylinders!
For applications in food related areas, "Klübersynth UH1 64-62" grease is used (customized version).
Grease gun
To relubricate the ball screw drive, use a grease gun suitable for the grease nipple.
We recommend a one-hand lubrication press with nozzle attachment type D1a4
(DIN3405). Both are optionally available:
nozzle attachment type D1a4 (DIN3405) - part No.: 180-006043
One-hand lubrication press with nozzle attachment type D1a4 (DIN3405) - part
No.: 180-006072
3.2.1. Relubrication via central lubrication port (standard)
Ø10
L
P
½ L
P
½ L
P
1
2
Figure 35: Relubrication via central lubrication port (standard)
1:
Central lubrication (standard)
2:
Central lubrication (Option)
Make sure that all external stops are removed.
Repeat the following process three times:
Retreat Electro Cylinder completely so that it touches the rear stop.
Move the cylinder by 0.5 mm into the internal buffer.
Ensure by means of control/controller that the internal buffer is not passed by
more than 0.5 mm!
This is the lubricating position.
Place the pipe orthogonally onto the lubricating nipple and press.
Use 1/3 of the defined amount of lubricant.
The amount of lubricant applied can be defined by the number of pump strokes.
Pump the stated amount of grease onto a balance, while counting the pump strokes.
For optimum distribution of the lubricant, a lubrication run must be performed
after each lubrication procedure. To do this, move the screw nut once over the
entire working stroke. For short-stroke applications (motion cycle < 2.5 spindle
rotation) see lubrication run lengths for short-stroke applications in the ETH
catalogue.