Maintenance and service
Operating / Mounting instruction
46 192-550003N10 ETH ATEX December 2019
3.2.2. Relubrication via central lubrication port (option)
Ø10
L
P
L
2
1
2
Figure 36: Relubrication via central lubrication port (option)
1:
Central lubrication (standard)
2:
Central lubrication (Option)
Lubrication port position
Depending on the cylinder size and the selected stroke, the relubrication hole is
located in the mid of the profile or in the mid of the stroke.
Stroke Stroke limit: L
2
= L
p
/2
Stroke < Stroke limit: L
2
= stroke / 2 + Offset
Pitch
Stroke limit [mm]
Offset [mm]
ETH032
M05
50 15
M10
M16
ETH050
M05
60 15
M10
M20
ETH080
M05
100 20
M10
M32
ETH100
M10
160 22
M20
ETH125
M10
240 25
M20
Start-up position of relubrication port
Assumption: Position = 0 at the rear buffer (lead screw completely retracted)
Position of center lubrication option [mm]
Pitch
Stroke stroke limit
[mm]
Stroke > Stroke limit
ETH032
M05
½ x stroke + 18
1/2 x stroke
M10
½ x stroke + 22.5
M16
½ x stroke + 24.5
ETH050
M05
½ x stroke + 18.5
M10
½ x stroke + 21.5
M20
½ x stroke + 27.5
ETH080
M05
½ x stroke + 24.5
M10
½ x stroke + 33.5
M32
½ x stroke + 48.5
ETH100
M10
½ x stroke + 59
M20
½ x stroke + 78
ETH125
M10
½ x stroke + 71
M20
½ x stroke + 115
The mentioned distances from the rear stop (on the motor side) to the central lubrication port in the profile are only reference values.
Loosen lubrication port screw.
Repeat the following process three times:
Move the cylinder slowly to its lubricating position until the lubricating port
becomes visible.