3.7.2.4. Cables and connectors associated to the resolver
To connect the motor with a connector M23 to PARKER drive : AC890, COMPAX3 or
SLVD, you can use complete cable with part number on the tabs below.
The "xxx" in the part number must be replaced by the length in meter.
Ex : for 20m cable, "xxx" = 020.
Cable reference
for AC890
Cable reference
for COMPAX3
For other drive, you can assembly cable and plug by soldering with part number on
the tab below:
3.7.2.5. Resolver setting
During the setting procedure, it is strictly necessary to respect the 3 following
conditions:
- The rotor must be able to rotate freely. The maximum friction torque on the
rotor must not exceed 1% of the motor permanent torque.
- The cooling circuit has to be in use.
- The operator must be able to reach the resolver stator and to manually turn it
and lock it (access to the locking screws).
Look at the drive instruction manual for the setting procedure details.