To mount the PHD into a vehicle mounting panel,
1. Install the PHD from the front.
2. Ensure that:
the PHD is oriented to the operator's viewing angle
the wire harness connects easily to the connectors and that the bend radius
is adequate
the harness is shielded from harsh impact
3. Secure the PHD using 4 screws or metal spring clips.
4. Install the bezel, typically provided by the customer (Parker does sell a snap-
on cosmetic bezel as an optional accessory).
The PHD may also be mounted from the rear of the panel without a bezel for a
flush appearance using insert studs and nuts.
Refer to the PHD drawing for panel cut-out dimensions:
Drawings and other documents may be found at www.parker.com/ecd or contact
your Parker representative.