7.1 Indoor temperature
Make indoor temperature settings as follows:
1) Touch the INDOOR TEMPERATURE section, the + and – buttons will be flashing.
Touch the + or – button to change the display unit (°C or °F).
2) Touch the INDOOR TEMPERATURE section again to set the indoor temperature high
alarm function, the +, ON/OFF and – buttons will be flashing, the HI AL icon will light
up. Touch the+ or – button to change the value, hold the+ or – button for 3 s to change
the number in larger steps. Touch the ON/OFF button to turn the alarm on or off (if
alarm is enabled, the speaker icon will be turned on, indicating the alarm function has
been enabled).
3) Touch the INDOOR TEMPERATURE section the third time to set the indoor
temperature low alarm function, the +, ON/OFF and – buttons will be flashing, the LO
AL icon will light up. Touch the+ or – button to change the value, touch and hold the+
or – button for 3 s to change the number in larger steps. Touch the ON/OFF button to
turn the alarm on or off (if alarm is enabled, the speaker icon will be turned on).
4) Touch the INDOOR TEMPERATURE section the fourth time to display the maximum
indoor temperature record. The maximum record will flash and the MAX icon will light
up. After holding the flashing MAX value for 3 s, the maximum value will be reset to
current reading.
5) Touch the INDOOR TEMPERATURE section the fifth time to display the minimum
indoor temperature record. The minimum record will flash and the MIN icon will light up.
After holding the flashing min value for 3 s, the minimum value will be reset to current
reading.