Troubleshooting
Problem Possible Solution
If the case does not tip-off or jams at the discharge end
…
Check adjustments on the tip-off guides and back stop.
Verify the case is sealed.
If the cases do not clear or begin to stack up at the tip-off
…
Check the High Level Discharge sensor.
Check PLC timing of High Level Discharge sensor.
Check that discharge conveyor is running.
If the machine jams …
Check the alarm banner on the HMI.
Check the set-up.
If the tape fails to apply or fails to cut …
Refer to the Troubleshooting section in the How-To.
If the problem is isolated and appears to be electrical …
Verify all sensors are properly operating.
Inspect for blown fuses or open circuit breakers.
Check the motors for thermal overloads.
Ensure sensors/reflectors are clean, aligned and operating.
Verify the sensors are not receiving false reflections from painted surfaces or external lights.
Check for faulty wiring or defective equipment.
Operations Manual CE35-T Case Erector
M-CE35T-2c Horiz Mag 3/2/2010
Troubleshooting
99