13. If the sensors need to be moved, loosen the at tach ment bolts.
14. From the front edge of the sensor mount to the center of the bolt on the
sensor bracket (approximately 7 to 7 ½”) position the Load Magazine Full
PE2 sensor.
a. Aim towards the Pick-Off Magazine Full PE3 sensor so the beams cross
at 4" (102 mm) to 5" (127 mm) from the corners of the blanks.
15. From the front edge of the sensor mount to the center of the bolt on the
sensor bracket (approximately 3 to 3 ½”) position the Pick-Off Magazine
Full PE3 sensor.
a. Aim towards the Load Magazine Full PE2 sensor so the beams cross at
4" (102 mm) to 5" (127 mm) from the corners of the blanks.
16.
Make sure bolts are suf fi ciently tight so that ma chine vi bra tion does not
cause the sensors to shift.
Operations Manual CE35-T Case Erector
M-CE35T-2c Horiz Mag 3/2/2010
How To
113
Fig. 88: Positioning the sensors
Attachment
Bolt
Load Magazine
Full PE2
sensor
Pick-Off
Magazine Full
PE3 sensor
7” to 7y
Front Edge of
Sensor Mount