3 Description
3.1 Technical specifications
Design specifications/ratings
Valve body Glass-filled Noryl
®
Rubber components Compounded for cold water
Weight (valve with controller) 1.8 kg
Recommended operating pressure 1.4- 8.6 bar
Water temperature 1- 38°C
Ambient temperature* 2- 50°C
Refill flow rate 0.53L/min- 1.25L/min
*Recommended for indoor use only.
Flow rates (valve only)
Service at 1.05bar drop 3.77m
3
/h
Backwash at 1.09bar drop 0.62 m
3
/h
Service Kv= 3.68 (Cv= 4.25)
Backwash Kv= 0.48 (Cv= 0.55)
Valve connections
Tank Thread 63.5mm(2½")- 8, male
Inlet/Outlet Thread 19mm(¾") BSPT, male
Drain line 12.7mm(½") BSPT, male
Brine line 9.5mm(⅜") BSPT male
Riser tube[Ø] 27mm(1.05")
Riser tube length Flush to top of tank ±12.7mm(½")
Electrical
Controller Operating Voltage 12VAC (requires use of Pentair Water supplied
transformer)
Input Supply Frequency 50 or60Hz
Motor Input Voltage 12VAC
Controller Power Consumption 6W average
Protection rating IP23