EasyManua.ls Logo

Pentair AUTOTROL 368 - Programming Mode Chart

Pentair AUTOTROL 368
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual Autotrol 368 (604-606) - Programming
Ref. MKT-IM-007 / D - 09.10.2020 33 / 60
3. Display Used to show informations, see Display [
Page32].
4. - Time button The time button when pressed will display the current hour of day
for 5seconds. Also used to change the time of day, see Time of
day [
Page34].
5. - Salt button The salt button when pressed will display the current salt setting
for 5seconds. Also used to change the brine dosage, see Brine
dosage [
Page34].
6. - Hardness button The hardness button when pressed will display the current
hardness setting for 5seconds. Also used to change the
volumetric regeneration, see Volumetric regeneration (606only)
[
Page34].
6.3 Programming mode chart
Parameter
description
Range of
values
Default
value
Units of
measure
Notes
Time of day 0:00- 23:59 12:00 hour:
minute
-
Brine dosage 0.2- 6.0 0.6 kg From 0.2kg to 1.0 kg by
increments of 0.05kg;
from 1.0 kg to 3.0 kg by
increments of 0.1kg;
from 3.0 kg to 6.0kg by
increments of 0.5kg.
Time clock
regeneration
(only604)
0  30 3 day 0= Disabled;
0.3= Regeneration every 8hours:
at 2, 10 and 18hours;
0.5= Regeneration every
12hours: at 2 and 14hours;
1- 30 = Regeneration every
Xdays.
Volumetric
regeneration
(only606)
0.4- 9.5 3.6 m
3
From 0.4m
3
to 1.0m
3
by
increments of 0.05m
3
;
from 1.0m
3
to 3.0m
3
by
increments of 0.1m
3
;
from 3.0m
3
to 5.0m
3
by
increments of 0.2m
3
;
from 5.0m
3
to 9.5m
3
by
increments of 0.5m
3
.

Table of Contents

Other manuals for Pentair AUTOTROL 368

Related product manuals