Installer manual Autotrol 368 (604-606) - Maintenance
Ref. MKT-IM-007 / D - 09.10.2020 45 / 60
Items 1 year 2 year 3 year 4 year 5 year
Turbine (if
present,
internal or
external
model)***
Check/ clean Check/ clean Check/ clean Check/ clean Replace
Turbine cable
(if turbine
present)
Check Check Check Check Replace
Valve
watertightness
Check Check Check Check Check
Valve to piping
watertightness
Check Check Check Check Check
* Electronical parts – durability strongly affected by power source quality and stability
** Elastomer durability is strongly affected by raw water concentration in chlorine and its derivate
*** Wear part.
9.3 Recommendations
9.3.1 Use original spare parts
Caution - material
Risk of damage due to use of non-genuine spare parts!
To ensure correct operation and safety of the device, only use original spare parts and
accessories recommended by the manufacturer.
Usage of non-genuine spare parts voids all warranties.
Parts to keep in stock for potential replacements are motor and optical sensor, controller,
transformer, injectors, flapper kit, O-ring kit, refill flow controller and DLFC.
9.3.2 Use original approved lubricants
• Production:
p/n 1014082 (NFO “Chemplex” 862 Silicone Comp.);
• spare part:
p/n 42561 (SILICONE LUBRICANT PACK).
9.3.3 Maintenance instructions
• Disinfect and clean the system at least once a year or if the treated water has an off-taste or
an unusual odor;
• perform a hardness test every year of both inlet and treated water.
9.4 Cleaning and maintenance
9.4.1 First steps
Before any cleaning or maintenance procedure, complete the following steps: