EasyManua.ls Logo

Pentair AUTOTROL 368 - Recommendations; Use Original Spare Parts; Use Original Approved Lubricants; Maintenance Instructions

Pentair AUTOTROL 368
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual Autotrol 368 (604-606) - Maintenance
Ref. MKT-IM-007 / D - 09.10.2020 45 / 60
Items 1 year 2 year 3 year 4 year 5 year
Turbine (if
present,
internal or
external
model)***
Check/ clean Check/ clean Check/ clean Check/ clean Replace
Turbine cable
(if turbine
present)
Check Check Check Check Replace
Valve
watertightness
Check Check Check Check Check
Valve to piping
watertightness
Check Check Check Check Check
* Electronical parts – durability strongly affected by power source quality and stability
** Elastomer durability is strongly affected by raw water concentration in chlorine and its derivate
*** Wear part.
9.3 Recommendations
9.3.1 Use original spare parts
Caution - material
Risk of damage due to use of non-genuine spare parts!
To ensure correct operation and safety of the device, only use original spare parts and
accessories recommended by the manufacturer.
Usage of non-genuine spare parts voids all warranties.
Parts to keep in stock for potential replacements are motor and optical sensor, controller,
transformer, injectors, flapper kit, O-ring kit, refill flow controller and DLFC.
9.3.2 Use original approved lubricants
Production:
p/n 1014082 (NFO “Chemplex” 862 Silicone Comp.);
spare part:
p/n 42561 (SILICONE LUBRICANT PACK).
9.3.3 Maintenance instructions
Disinfect and clean the system at least once a year or if the treated water has an off-taste or
an unusual odor;
perform a hardness test every year of both inlet and treated water.
9.4 Cleaning and maintenance
9.4.1 First steps
Before any cleaning or maintenance procedure, complete the following steps:

Table of Contents

Other manuals for Pentair AUTOTROL 368

Related product manuals