Installer manual Autotrol 368 (604-606) - Programming
32 / 60 Ref. MKT-IM-007 / D - 09.10.2020
6 Programming
Info
After 5seconds without keypad input, the unit returns to normal operation mode and
display the time of day.
Memory retention in case of power failure : the controller stores the time of day
without battery in case of power failure. All others programmed parameters are stored
in the nonvolatile (Novram) memory and are stored during power failure. The storage
time in the flash memory is about 99years.
has two different functions according to the controller used:
For 604controllers: the function is the day interval setting.
For 606controllers: the function is the volumetric capacity setting.
6.1 Display
1. Digits Two digits used to display the time, program value or error codes.
2. Flow indicator The flow indicator blinks ON andOFF when water flow turns the
meter.
3. Delayed regeneration
indicator
When this dot is displayed, it means that a delayed regeneration is
programmed.
6.2 Commands
1. Camshaft indicator A column of windows provides a visual indicator of the camshaft
rotation.
2. - Manual regeneration
button
The manual regeneration button when pressed initiates either a
delayed regeneration or immediate regeneration.