Installer Manual Fleck 4600 - MECH - Description
Ref. MKT-IM-027 / B - 01.06.2018 21 / 88
3.5. Configurations for volumetric and time clock softeners
To configure the valve as volumetric or time clock softener, the 24 hour gear, the skipper or program
wheel and the meter must be set as shown below.
3.5.1. Volumetric
Meter assy 8 m
3
PN 24107
Meter assy 40 m
3
PN 25871
Program wheel assy 8 m
3
PN 24119
Program wheel assy 40 m
3
PN 24120
24 hour gear
PN 13009-21SP