Installer Manual Fleck 4600 - MECH - Programming
48 / 88 Ref. MKT-IM-027 / B - 01.06.2018
6.3. Time clock
6.3.1. Calculating the number of days between two regenerations
Set the number of days between two regenerations using the following formulas:
Water capacity [m
3
] = (Exchange capacity [m
3
°tH] - Reserve capacity [m
3
]) / Water hardness [°tH]
Number of days between regenerations = Water capacity [m
3
] / Daily water consumption [m
3
]
1. 24 hour wheel
2. Program wheel → Defines the number of days between two regenerations.
3. Time of day → Shows the current time.
4. Service position → Service;
→ Regeneration;
→ Backwash;
→ Brine draw/slow rinse;
→ Brine refill.
5. Red lamp → Lights when the valve regenerate.
6. Green lamp → Lights when in service.