EasyManua.ls Logo

Pentair Fleck 4600-MECH - Time clock

Pentair Fleck 4600-MECH
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 4600 - MECH - Programming
48 / 88 Ref. MKT-IM-027 / B - 01.06.2018
6.3. Time clock
6.3.1. Calculating the number of days between two regenerations
Set the number of days between two regenerations using the following formulas:
Water capacity [m
3
] = (Exchange capacity [m
3
°tH] - Reserve capacity [m
3
]) / Water hardness [°tH]
Number of days between regenerations = Water capacity [m
3
] / Daily water consumption [m
3
]
1. 24 hour wheel
2. Program wheel → Defines the number of days between two regenerations.
3. Time of day → Shows the current time.
4. Service position → Service;
→ Regeneration;
→ Backwash;
→ Brine draw/slow rinse;
→ Brine refill.
5. Red lamp → Lights when the valve regenerate.
6. Green lamp → Lights when in service.

Table of Contents

Related product manuals