Installer Manual Fleck 4600 - MECH - Programming
Ref. MKT-IM-027 / B - 01.06.2018 51 / 88
6.4.2. Set the salt volume per regeneration
No. Operation
A
Calculate the weight of salt needed per regeneration, see 6.4.1. Salt volume definition,
page 50.
B Remove the screws (2) and the cover (1).
C Loosen (5).
D Adjust the segment of the brine cam (4) to the value calculated at point A on the sticker (3).
E Tighten (5).
F Replace the screws (2) and the cover (1).
Note
Example for the following drawing, the weight of salt set is 2 kg per regeneration.