EasyManua.ls Logo

Pentair MT125 - Error and Fault Codes

Pentair MT125
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
460906 Rev. D 8/2020 MASTERTEMP
125 Pool and Spa Heater Installation and User’s Guide
49
Error and Fault Codes
Table 8. Heater Error and Fault Codes
Fault Condion
Error Code
Displayed
Note
Troubleshoo�ng
Water pressure switch
open
ERR PS
If water ow is established the
the error is cleared and normal
operaon is resumed.
No water ow thru
heater
Hi temperature limit
switch open
ERR HLS
When the temperature falls
below 135°F the error is cleared
and normal operaon is
resumed.
Water temperature aer
the 1
st
pass through the
heater exchanger is more
than 135°F.
Air ow switch open
ERR AFS
If adequate air ow through the
blower is established within 60
seconds the heater will resume
normal operaon. If the error is
not corrected within 60 seconds
the heater will need to turned
o by pressing the HEATER OFF
buon.
The blower is not on or
air thru it is being
restricted
Ignion Control Module
ERR IGN
To clear the error the HEATER
OFF buon must be pressed.
The Ignion Control
Module was not able to
ignite the heater.
Automac gas shuo
ERR AGS
The front panel buons will be
disabled. To reset the heater,
cycle power.
Water temperature aer
the 2
nd
pass thru the heat
exchanger is more than
140°F
Excessive stack ue
temperature
ERR SFS
The front panel buons will be
disabled. To reset the heater,
cycle power.
The temperature of the
stack ue is more than
480°F
Open stack ue sensor
E05
Shorted stack 
sensor
E06
The front panel buons will be
disabled. To reset the heater,
cycle power.
Follow diagram on page
53/54
Open water
temperature sensor
E01
To clear the error the HEATER
OFF buon must be pressed.
Follow diagram on page
53/54
Shorted water
temperature sensor
126
Follow diagram on page
53/54
Follow diagram on page
55
Section 3. Troubleshooting

Table of Contents

Related product manuals