K23-SSI/USB/25B-C | OPERATING SOFTWARE OS6.0
25
Value
Designation
Function
5
A/B x 90°
Frequency measurement with A/B x 90° signal.
(Forward/backward—rotation direction
monitoring)
FREQUENCY BASE
Sets the desired base for frequency measurement (resolution).
Value
Function
0
1 Hz
(Interpretation of result in format: xxxxxxxx Hz)
1
1/10 Hz
(Interpretation of result in format: xxxxxxx.x Hz)
2
1/100 Hz
(Interpretation of result in format: xxxxxx.xx Hz)
3
1/1000 Hz
(Interpretation of result in format: xxxxx.xxx Hz)
SAMPLING TIME 1 (S)
The set value is the minimum measuring time (for channel A) in seconds. The
sampling time acts as a filter for irregular frequencies. This parameter directly
affects the reaction time of the device.
Value
Function
0.001
Minimum measuring time in seconds
0.1
Default value
9.999
Maximum measuring time in seconds