EasyManua.ls Logo

Pepperl+Fuchs K23-SSI/USB/25B-C - WAIT TIME 1 (S); STANDSTILL TIME 1 (S); AVERAGE FILTER 1 (average determination)

Pepperl+Fuchs K23-SSI/USB/25B-C
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K23-SSI/USB/25B-C | OPERATING SOFTWARE OS6.0
26
WAIT TIME 1 (S)
The set value is the zero setting time. This parameter defines the duration
of the lowest frequency, or the waiting time between two rising edges on
channel A, at which the device detects the 0 Hz frequency. Frequencies
with a duration greater than the set WAIT TIME 1 are evaluated as
frequency = 0 Hz.
Value
Function
0.01
Frequency = 0 Hz for frequencies less than 100 Hz
1.00
Default value
79.99
Frequency = 0 Hz for frequencies less than ~ 0.01 Hz
STANDSTILL TIME 1 (S)
This parameter defines the downtime. If frequency = 0 Hz is detected at
channel A, a downtime is signaled after xx.xx seconds and the startup
override is reactivated. Downtime monitoring can be set in the
PRESELECTION menu.
Value
Function
0.01
Shortest delay time in seconds
99.99
Longest delay time in seconds
AVERAGE FILTER 1 (average determination)
Switchable average determination or filter function at unstable frequencies at
input A for smoothing the analog signal. If the filter is set to 5 … 16, the device
uses an exponential function. The time constant T (63 %) corresponds to the
number of sampling cycles.
For example, SAMPLING TIME = 0.1 s and AVERAGE FILTER = exponential
filter,
T (63 %) = 2 x sampling time.
This means that after 0.2 s, 63 % of the jump height is reached.

Related product manuals