STANDSTILL TIME(s)
This parameter defines the downtime. When downtime is detected, a downtime
signal is signaled after xx.xx seconds.
AVERAGE FILTERSPEED (filter for average determination)
Switchable average determination for preventing velocity fluctuations.
Value
Function
0
No average determination
1
Flowing average determination with two cycles
2
Flowing average determination with four cycles
3
Flowing average determination with eight cycles
4
Flowing average determination with 16 cycles
4.6 Serial Menu
The default settings for the serial interface are defined in this menu.
UNIT NUMBER
This parameter can be used to set serial device addresses. The devices can be
assigned addresses between 11 and 99. Addresses that contain a "0" are not
allowed since these are used as group or collective addresses.
Value
Function
11
Smallest address without zero
-
99
-
Note
Device address is fixed to "11" for USB interface and cannot be adjusted
Value
Function
0.01
Shortest delay time in seconds
99.99
Longest delay time in seconds

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pepperl+Fuchs K23-SSI/USB/25B-C and is the answer not in the manual?

Pepperl+Fuchs K23-SSI/USB/25B-C Specifications

General IconGeneral
BrandPepperl+Fuchs
ModelK23-SSI/USB/25B-C
CategoryMedia Converter
LanguageEnglish

Related product manuals