EasyManua.ls Logo

Perkins M190C - Customer Specified Parameters

Perkins M190C
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KENR9126 33
Troubleshooting Section
Customer Specied
Parameters
i04012393
Customer Specied
Parameters
Customer specied parameters allow the engine to
be congured to the exact needs of the application.
Customer parameters may be changed repeatedly as
a customer's operation changes.
The following information is a brief description of
the customer specied parameters. The following
parameter values are included with the descriptions:
Minimum
Maximum
Default
Engine Rating Parameter
Rating Number
The rating number is the selected rating within a
power rating family. The ash le denes the power
rating family. The ash le contains two ratings. The
rating number denes the power rating that is used
within the power rating family.
Table 8
Minimum Maximum Default
121
Low Idle Parameters
Low Idle Speed
The Low Idle Speed” is the minimum engine rpm.
Table 9
Minimum Maximum Default
60
0rpm
75
0rpm
60
0rpm
ECM Identication Parameter
Equipment ID
“Equipment ID” is the identication of the equipment
that is assigned by the customer. The “Equipment
ID” is only for reference only by the customer. The
“Equipment ID is not required by the Electronic
Control Module (ECM).
Table 10
Value Default
17 digits
The available characters
are dependent on the
service tool that is
being used.
Not programmed
Congurable Inputs
Coolant Level Sensor
A coolant level sensor is an optional switch input.
Programming the “Coolant Level Sensor” parameter
to “Enabled” noties the ECM that a coolant level
sensor input is present on pin J1:45. If this parameter
is programmed to “Enabled” and the coolant level
falls below the measured level, the “E2143-1” and
“E2143-2 event codes will be displayed.
Table 11
Value
Default
Installed
Not In
stalled
Not Installed
Fuel/
Water Separator Switch Installation
Status
Afue
l/water separator switch is an optional switch
input. Programming the “Fuel/Water Separator
Switch Installation Status” parameter to “Enabled”
noti
es the ECM that a fuel/water separator switch
input is present on pin J1:44. When this parameter
is programmed to “Enabled” and the fuel/water
sep
arator switch closes, an “E232-1” or J97-15
event code will be displayed.
Table 12
Value
Default
Installed
Not Installed
Installed

Table of Contents

Related product manuals