KENR9126 91
Troubleshooting Section
Troubleshooting:
This fault can be caused by a sensor that is shorted
to ground or a sensor that is internally shorted.
Perform the following diagnostic procedure: “Engine
Temperature Sensor Open or Short Circuit - Test”
Results:
OK STOP.
i04010710
CID 0174 FMI
03
Conditions Which Generate This Code:
The Electr
onic Control Module (ECM) detects a
signal voltage from the sensor that is above normal.
System Re
sponse:
The ECM will log the diagnostic code. The ECM ags
fuel tem
perature as invalid data and fuel temperature
is set to a default value.
Possibl
e Performance Effect:
There are no performance effects.
Troubleshooting:
Perfor
m the following diagnostic procedure: “Engine
Temperature Sensor Open or Short Circuit - Test”
Resul
ts:
OK STOP.
i040
10712
CID 0174 FMI 04
Con
ditions Which Generate This Code:
The Electronic Control Module (ECM) detects signal
vol
tage that is below normal.
System Response:
The ECM will log the diagnostic code. The ECM ags
fuel temperature as invalid data and a default value
is
used.
Possible Performance Effect:
There are no performance effects.
Troubleshooting:
Perform the following diagnostic procedure: “Engine
Temperature Sensor Open or Short Circuit - Test”
Results:
OK STOP.
i04018149
CID 0177 FMI
03
Conditions Which Gen erate This Code:
The signal
voltage from the transmission oil
temperature sensor is above normal.
System Res
ponse:
The Electronic Control Module (ECM) will log the
diagnost
ic code. The transmission oil temperature
will be set to a default value.
Possibl
e Performance Effect:
There are no performance effects.
Troubleshooting:
Perfor
m the following diagnostic procedure:
“Transmission Oil Temperature Sensor Open or Short
Circuit - Test”
Results:
OK ST
OP.
i04018150
CID 0
177 FMI 0 4
Conditions Which Gen erate This Code:
The
signal voltage from the transmission oil
temperature sensor is below normal.
Sys
tem Response:
The Electronic Control Module (ECM) will log the
di
agnostic code. The transmission oil temperature
will be set to a default value.
Po
ssible Pe rformance Effect:
There are no performance effects.