Error
36
10.10 Error messages
Error code Description
Error 1 System error
Error 2 Sewing motor ERROR 2/BB/xxx
BB = 20: Deadman
10: Speed
0B: StopX
0A: Reset stitch counter
09: Write parameters
05: Position t.d.c. by shortest route
03: Position t.d.c. in reverse
02: Position t.d.c. forwards
30: Timeout for increasing speed
31: Timeout from uncertain positioning
32: Timeout from deadman command
33: Timeout for deleting errors
34: Timeout for emergency stop
35: Timeout for writing parameters
36: Timeout for resetting stitch counter
37: Timeout for stop command after x stitches
38: Timeout for initialisation
xxx = sewing motor control
unit error (see Motor errors)
39: Establishing contact when turned on
Error 3 Ramp memory too small
Error 4 free
Error 5 Stacker not ready(3)
Error 6 Sewing head sewing position/thread-in position
(sensor monitoring)
Error 7 Stepping motor movement
1. Ramp X not ready
2. Ramp Y not ready
3. Time monitoring
Error 8 Needle thread monitor
Error 9 Bobbin thread monitor
Error 11 Stepping motor step frequency too high
Error 21 Power supply unit overloaded (24 V)
Error 22 Mains voltage
Error 23 Power supply 24 V too low