PG DRIVES TECHNOLOGY NEWVSI TECHNICAL MANUAL – PROGRAMMING
SK80151-1 43
Adjustable between 1 and 200 in steps of 1.
If this value is set lower than the Deceleration value, then the latter value will be used for fast braking.
6.2 Soft Stop Rate
Adjusts the deceleration rate that is used while the wheelchair is soft-stopping. Soft-stopping happens if the newVSI is switched off
while the wheelchair is being driven.
Adjustable between 0 and 200 in steps of 1.
6.3 Front Wheel Drive Rate
Front Wheel Drive Rate adjusts the driving characteristics of the newVSI to suit a wide range of front wheel drive wheelchairs.
Adjustable between 1 and 100 in steps of 1.
Increasing this value means that the newVSI's software is more suitable for higher speed front wheel drive wheelchairs.
6.4 Soft Reverse Deceleration
Adjusts the deceleration rate used while the wheelchair is stopping in reverse. This rate is separately adjustable from the
Deceleration parameter, to prevent the wheelchair tipping when reversing down a gradient.
Adjustable between 25 to 100% in steps of 1%.
The value is a percentage of the Deceleration parameter.
A typical value is 70%.
6.5 Reverse Driving Alarm
Sets whether the newVSI gives an audible warning while driving in reverse. The parameter can be set to on or off.
On Means there is an audible alarm given.
Off Means there will be no audible alarm.
6.6 Brake Disconnected Alarm
Sets whether the newVSI gives an audible warning while the wheelchairs electrical brakes are disconnected. The parameter can
be set to on or off.
On Means there is an audible alarm given.
Off Means there will be no audible alarm.
6.7 Lock Function Enabled
Sets whether the newVSI’s locking sequence can be used to prevent the wheelchair being driven by unauthorized persons. The
parameter can be set to on or off.
On Means the Lock function is available.
Off Means the Lock function is not available.
6.8 Brake Fault Detect
Sets whether the newVSI detects a fault in the wheelchair’s electrical brakes or the connections to them. The parameter can be
set to on or off.
On Means the newVSI will detect brake faults.
Off Means the newVSI will not detect brake faults.