PHILIPS 3000 V2 04 SERVICE MODE
4/9
Level 2 (Input)
Start condition: NO BU, NO drag drawer, door open, no
Water Spout or Carafe (only AMF), and No Water sensor
LED INDICATION
Led NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
ON*onlyAMF ON ON ON
InsertafullWaterTank
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch o Red Leds NoWater NA OFF NA NA
ERROR: Led NoWater remains on, check the capacitive
sensor (xing) and the wiring (JP23)
NA ON NA NA
Finishcondition:NO BU, NO drag drawer,
door open and No Water sensor
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Led
Descale
Led
Rinsing
OFF OFF OFF OFF OFF OFF
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Led
Descale
Led
Rinsing
Switch on Red Leds Dreg drawer full & No-
Beans
ON OFF OFF ON OFF OFF
ERROR: Led NoBeans remains o, check the inter-
face board and at cable (JP21)
OFF ON
ERROR: Led Dreg drawer full remains o, check
the interface board and at cable (JP21)
ON OFF
ERROR: Led NoBeans & Dreg drawer full remain
o, check the interface board and at cable (JP21)
OFF OFF
Press“EspressoLungo”(CMF)or“EasyCappuccino”(AMF)Button
PressSteam/HotWaterButton
Action by user LED INDICATION
Led Steam/Hot-Water Button Led Aroma Plus Button
Switch on green Led under the Steam/Hot-
Water Button
ON OFF
ERROR: Led Steam/Hot-Water remains o,
check the interface board and at cable (JP21)
OFF OFF
Press AromaPlus Button
Action by user LED INDICATION
Led Steam/Hot-Water Button Led Aroma Plus Button
Switch on green Led under the Aroma Plus
button
OFF ON
ERROR: Led Aroma Plus remains o, check
the interface board and at cable (JP21)
OFF OFF