PHILIPS 3000 V2 04 SERVICE MODE
5/9
Finishcondition: With BU, Drag Drawer, door closed
and Tank
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF OFF OFF OFF
InserttheBrewUnit
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch o Red Leds GenAlarm NA NA OFF NA
ERROR: Led GenAlarm remains on, check the BU presen-
ce Microswitch and the wiring (JP16).
NA NA ON NA
InsertWaterSpout*OnlyAMF
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch o Red Leds NoBeans OFF NA OFF NA
ERROR: Led NoBeans remains on, check the Carafe Board
and the wiring (JP4).
ON NA NA NA
InsertDregdrawerandclosetheservicedoor
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch o Red Led Dreg drawer full NA NA NA OFF
ERROR: Led Dreg drawer full remains on, check the Mi-
croswitch for the door and the wiring (JP14).
NOTE: without the Dreg drawer correctly inserted the in-
dication cannot change!
NA NA NA ON
PresstheEspressobuttontomoveBUtowork
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
When the BU reaches the work position the Led NoBeans
is switched on
ON NA NA NA
ERROR: Led NoBeans remains o, Check the work mi-
croswitch (broken?), the BU motor (blocked?) and the wi-
ring (JP16).
NA NA NA NA
ERROR: led GenAlarm Switch ON; the absorbed current
is much more 300mA (with BU) or 200mA (without BU)
check the BU and the motor
NA NA ON NA
Start condition: NO BU, Drag drawer, door Closed and
No Water sensor
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF OFF OFF OFF
If the Dreg drawer is not inserted or the Service door is
not closed the BU test cannot be performed. If these 2
inputs are not in the right position, Led Dreg drawer full
will be RED
NA NA NA ON
Level 3 (Brewing unit)