9.2 Register assignment
The following table shows how the device registers are assigned to addresses that can be
accessed via Modbus/RTU.
Unless otherwise specified, the numerical values are decimal values.
Table 9-2 Register assignment
Type Address Value Access Memory Function Coding
Input 1000-
1015
16 bits Read Retentive Order designation ASCII (32 characters)
1016-
1020
16 bits Read Retentive Order number ASCII (10 characters)
1021-
1026
16 bits Read Retentive Serial number ASCII (12 characters)
16 bits Retentive
1027 16 bits Read Retentive Year of manufacture YYYY (4 x 4 bits BCD)
1028 16 bits Read Retentive Manufacturing date MM.DD (4 x 4 bits BCD)
1029 16 bits Read Retentive Hardware identification ASCII (MSB) + integer (LSB)
1030 16 bits Read Retentive Hardware version Integer
1031 16 bits Read Retentive Firmware: identification letter
and major version number
ASCII (MSB) + integer (LSB)
1032 16 bits Read Retentive Firmware: version number Integer
1033 16 bits Read Retentive Firmware: minor version num-
ber
Integer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phoenix Contact EV Charge Control Basic and is the answer not in the manual?

Phoenix Contact EV Charge Control Basic Specifications

General IconGeneral
BrandPhoenix Contact
ModelEV Charge Control Basic
CategoryController
LanguageEnglish

Related product manuals