PNOZ s5
Operating Manual PNOZ s5
21397-EN-10
8
Unit features
} Positive-guided relay outputs:
2 safety contacts (N/O), instantaneous
2 safety contacts (N/O), delay-on de-energisation
} 1 semiconductor output
} Connection options for:
E-STOP pushbuttons
Safety gate limit switches
Start buttons
Light grids and safety switches with detection of shorts across contacts
} A connector can be used to connect 1 PNOZsigma contact expansion module
} Operating modes and delay times can be selected via rotary switches
} LED indicator for:
Supply voltage
Input status, channel1
Input status, channel2
Switch status channel 1/2
Start circuit
Error
} Plug-in connection terminals (either spring-loaded terminal or screw terminal)
} See order reference for unit types
Safety features
The relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
} The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.