First commissioning
Operating Manual PSEN sc B 5 Series
1004508-EN-02
47
9 First commissioning
9.1 Requirements for commissioning
Please note:
} Ensure that the window of the safety laser scanner is clean, intact and without finger-
prints.
CAUTION!
Detection of violations of the protected field deteriorates
If the safety laser scanner is commissioned in other conditions, the detec-
tion of violations of the protected field may deteriorate.
– Ensure that the conditions for commissioning are met.
9.2 System connection
Make sure that the selected evaluation device has the following property:
} OSSD signals are evaluated through 2 channels with feasibility monitoring
7
5
6
0 V24 V
0 V
OSSD 1
OSSD 2
24 V
0 V
1
2 24 V
F.E.8
PSENscan
4 n.c.
3
n.c.
Evaluation device
Input circuit
External
supply voltage
Warning message
Indicator light unit
Fig.: Dual-channel connection of the safety laser scanner on the input circuit of an evaluation device
(1 zone set, warning message, automatic restart)