2-2 Operating Manual: PSS 3075-3 Series
For non-safety-related applications, the PSS can be connected to various
standard bus systems (e.g. PROFIBUS-DP). The bus interfaces that are
available will depend on the unit type.
INFORMATION
The standard bus interfaces are described in separate operating
manuals. The necessary operating manuals are supplied with the rele-
vant unit types.
Drivers (standard function blocks) from the corresponding Pilz software
package will be required in order to connect to the various standard bus
systems.
Example:
PSS SB 3075-3 ETH-2
Safety systems PSS 3075-3 with SafetyBUS p- and Ethernet interface.
The digital inputs can be used for local emergency stop monitoring, for
example. They are suitable for connecting single or dual-channel input
devices, with or without test pulses. The test pulse outputs are suitable for
testing input devices.
The single or dual-pole outputs can be used to drive valves, for example.
SafetyBUS p enables you to establish a safe decentralised network of
several programmable safety systems and/or to connect decentralised
modules. The PSS can perform the function of a Management, Logic or
Input/Output Device on SafetyBUS p.