EasyManua.ls Logo

Pilz PSS 3075-3 Series - Example: Single-Channel, Failsafe Input Device, Without Test Pulse

Pilz PSS 3075-3 Series
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Wiring the Inputs and Outputs
7-6 Operating Manual: PSS 3075-3 Series
Example: Single-channel, failsafe input device, without test pulse
Features:
Depending on the application area and its respective regulations, this
connection diagram is suitable for input devices with frequent and
infrequent operation in accordance with EN 954-1, up to category 2.
The possibility of a short circuit occurring in the external wiring between
different inputs or against L+ must be eliminated through appropriate
wiring.
The input device must be approved for failsafe applications.
Please read the instructions provided with the input device.
CAUTION!
A short circuit in the cable between the input device and input with the L+
line or between adjacent inputs will not be detected. Neither will a short
circuit between several input devices be detected. Depending on the type
of input device connected, this could create a risk to both personnel and
machinery (e.g. E-STOP). Always ensure that the unit is suitably wired to
eliminate the risk of short circuits.