Safety
PSS(1) ControlNet Adapter - Hardware Manual3-4
Installing the module
Please read the Safety Manual and the Installation Manual for the
relevant PSS before installing and commissioning the module.
Keep as large a distance as possible between the PSS and any
electromagnetic fields, particularly when frequency converters are
nearby. Where necessary, use suitable screening to separate the PSS
from the source of interference
Ensure the maximum ambient and operating temperatures are not
exceeded
Avoid the build up of heat
Protect the module from direct sunlight and dust.
Ensure that liquids or objects cannot get into the module
Do not use chemicals close to the module
Do not position the module close to flammable materials.
Cable material and cable layout
NOTICE
Only use screened cables and follow any requirements laid down by
ControlNet.
Measures to protect against interference
Follow any requirements laid down by ControlNet.
Assembling and connecting the module
• Only install the module when no voltage is applied
• The information given in “Technical Details” must be followed.

Other manuals for Pilz PSS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PSS Series and is the answer not in the manual?

Pilz PSS Series Specifications

General IconGeneral
CategorySafety Equipment
ManufacturerPilz
Safety StandardsEN ISO 13849-1, IEC 61508, IEC 62061
SeriesPSS
Safety Integrity LevelSIL 3
Communication InterfacesEthernet, PROFIBUS, PROFINET
Operating Voltage24 V DC
Operating Temperature0°C to +55°C (typical), others depending on model
Storage Temperature-20°C to +70°C (typical), others depending on model
Protection ClassIP20
ApplicationIndustrial safety applications