EasyManuals Logo

Pima FORCE Programming Guide

Pima FORCE
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18
PIMA Electronic Systems
Parameter
Description
Default
Range
System ID
A parameter required by the NPAF protocol only.
Consult the CMS.
0
-
ACKs
Handshake Wait: how long the control panel will wait
for a Handshake message, before disconnecting the call
and redialing.
20 sec.
20-250
sec.
Kissoff Wait: how long the control panel will wait for a
Kissoff message, before resending it. Change the
default only if necessary, for example if there are
communication delays.
0 mS.
1-5000
mS.
ACK Frequency: select between Lo-Hi, 1400, 2300, and
SIA.
Lo-Hi
-
Periodic Test
A daily test report to the CMS; press # to reset and
disable reporting.
-
-
Test Interval
An interval (in hours) for a test report to the CMS. If
longer than 24 hours, the interval will start over every
time it overlaps the Periodic test.
-
-
Number of
Dials
The number of dials and redials that if fail (no ACK is
received), a communication fault is reported.
-
-
Primary Path
Select if the telephone is the primary path for reporting
the CMS.
-
-
2) Cellular-Voice: see the Telephone (PSTN) menu above.
3) Network (Ethernet): in addition to the above Telephone (PSTN) parameters, the network
has the following parameters:
Parameter
Description
Default
Range
Network
Addresses
IP/URL 1-2: the CMS’s IP/URL address. Address #2 only serves as a backup.
Port 1-2: enter the port no.
Supervision
Supervision (test) report interval. The report is
designated to the IP receiver at the CMS.
5 min
0 (disabled) -
59:59 mm:ss
Retries
Set the number of retries if no ACK is received.
10
2-250
Disable
Encryption
Data will be not encrypted. Verify that CMS IP
receiver is adjusted for non-encrypted reports.
Caution
Non-encrypted reporting causes the system and
the CMS to be more vulnerable to cyber attacks!
16 digits
Acc. ID
The account ID field in the report frame will
always be 16 digits, with leading '0'. Use this
feature only by special request from the CMS.
4) Cellular Data: see Network (Ethernet) above.
Event Reporting
System Configuration
CMS & Communications
Monitoring Stations
CMS 1-3
Event Reporting
Select the events to report to the CMS. The optional events are:
Alarms: Burglary, Panic, Fire, Duress, Medical, Tamper, Custom Zone 1-5.