24
PIMA Electronic Systems
8 Timers and Counters
The
Timers and Counters
menu includes the following parameters.
Parameter
Description
Default
Range
Programmable
Output Types
See next section.
Entry Delay
1-2
A period that allows entering the premises
through delayed and follower zones, and
disarming (system/partition) without triggering
an alarm.
30/60 sec.
0-250
Exit Delay
A period that allows exiting the premises
through delayed and follower zones, after
arming (system/partition) without triggering
an alarm.
30 sec.
Double Knock
A period during which only if a detector activates
twice, it triggers an alarm.
Cross Zoning
A period during which only if two cross-zones
activate, an alarm is triggered.
Soak Test
A number of days during which the zone is in test
mode: if it activates it will not trigger an alarm (but
the event will be recorded). The zone is
automatically reinstated.
3 days
1-7
Bypass Limit
A time limit before arming the alarm system (or
a partition) during which a zone can be bypassed
by a user. The zone is un-bypassed when the
timer elapses or the alarm system/partition is
disarmed, whichever comes first.
0 hr.
0-250
Auto-Bypass
Limit
A period during which a zone that was
automatically bypassed after triggering the alarm
three times during one arming session is
reinstated.
Inactivity
A period (days) during which if the alarm system
has not been armed, ContactID event no. 654 is
reported.
7 days
0-99
Code
Keystrokes
The number of allowed keystrokes, when
entering codes. Any more keystrokes will trigger
an alarm and lock the keypad; see next. To reset
the counter, wait 30 seconds.
24
10-250
Keypad Lockout
A period during which the keypad is locked, due
to illegal number of keystrokes (see above).
180 sec.
0-250
Siren beep
The arming/disarming indication beep length
300 mSec
0-1000
Report Delay
AC Fault
Telephone fault
Cellular Modem Fault
Network Fault
The time between the occurrence of the fault and
reporting the event. If the fault is fixed before the
delay expires, no event is reported.
120
min
0-
250