EasyManua.ls Logo

Pioneer PDP-60MXE20

Pioneer PDP-60MXE20
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
Special Installation (Embedding in the wall)
A
A
A
X (Front of the unit)
<Viewed from Above>
<Viewed from the Right Side>
Operating Temperature Restrictions
Temperature in space X and Y
A: 0 mm to 370 mm 0 °C to 40 °C
* The same operating temperature restrictions apply to the speaker system (PDP-S55-LR).
Y (Rear of the unit)
3.4.3 Embedding in the wall
Carefully read the following imformation before trying to embed the unit in a wall. Observe all the limitations specified
below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (no obstructions within a distance of 300 mm from the
back surface of the unit).
A
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
.
Before attaching the unit to fittings, double-check that the thickness and height of the fittings,
and the number of bolts is correct.
(Also refer to 3.4.1 Mounting to fittings (pg. 25).)

Table of Contents

Related product manuals