ENGLISH
26
Frequent Flare-Ups Cooking Temperature Attempt cooking at a lower temperature. Grease does have a flash point. Keep the temperature under
176°C / 350°F when cooking highly greasy food.
Grease Build-Up On
Cooking Components
Follow
Care and Maintenance
instructions.
ErP Error Code Grill Probe Check status of grill probe. Follow
Care and Maintenance
instructions if dirty. Contact Customer Care
for a replacement part if damaged.
ErH Error Code The Unit Has
Overheated, Possibly
Due To Grease Fire Or
Excess Fuel
Press the Power Button to turn the unit off, and allow grill to cool. Follow
Care and Maintenance
instructions. After maintenance, remove pellets, and confirm positioning of all component parts. Once
cooled, press the Power Button to turn the unit on, then select desired temperature. If error code still
displayed, contact Customer Care.
ErL Error Code Grill fails to perform
start-up cycle
Check proper positioning of cooking components. Check hopper for sufficient fuel or if there is an
obstruction in the feed system. Remove pellets and follow
Care and Maintenance
instructions. Check
grill probe. Confirm if actual temperature is correct and accurate. Follow
Care and Maintenance
instructions if dirty. Check ignitor positioning and that it is heating up properly. In extreme cold, the
grill may require a second start. Turn grill off, wait, then turn on again. Check fan. Ensure it is working
properly. Follow
Care and Maintenance
instructions if dirty.
Grill will not stay lit
Err Error Code with
PELLET Icon Blinking
Lack Of Fuel, Poor Fuel
Quality, Obstruction In
Feed System, Jammed
Auger
Check hopper to check that fuel level is sufficient and replenish if low. Should the quality of wood
pellets be poor, or the length of the pellets too long, this may cause an obstruction in the feed system.
Remove pellets and follow
Care and Maintenance
instructions.
Err Error Code
with IGNITOR Icon
Blinking
Ignitor is not working
properly, not making a
connection
Remove ash clean-out tray. Press the Power Button to turn the unit on and inspect the igniter. Confirm
that the igniter is working by placing your hand above the feed system and feeling for heat. If not
operating properly, call Customer Care for assistance or a replacement part.
Ignitor failure Igniter needs to be replaced. Contact Customer Care for replacement part.
Err Error Code with
AUGER Icon Blinking
Auger not primed Before the unit is used for the first time or anytime the hopper is completely emptied out, the auger
must be primed to allow pellets to fill the feed system. If not primed, the igniter will timeout before
the pellets ignite. Follow
Hopper Priming Procedure
.
Auger motor is jammed,
not making connection
Remove ash clean-out tray. Press the Power Button to turn the unit on and inspect the auger feed
system. If not operating properly, call Customer Care for assistance or a replacement part.
Err Error Code with
FAN Icon Blinking
Fan is not working
properly, not making a
connection
Check fan. Ensure it is working properly and air intake is not blocked. Remove fan cover (see
Electric Wire Diagram
), and check for any damage to the fan wires. Follow
Care and Maintenance