Page #19 background imageLoading...
Page #19 background image
NOTE
Do
not
leave
the
fryer
unattended
during
cleaning.
Never
let
the
water
level
go
below
the
"Min
Level"
mark
on
the
back
of
the
tank.
e.
Using
the
fryer
cleaning
brush,
scrub
the
inside
of
the
fryer
to
remove
protective
coating.
f.
When
cleaning
is
complete,
Press
the
OFF
side
of
the
OFF-ON-START
switch
to
turn
the
fryer
off.
Drain
the
water
into
a
container
suitable
for
hot
water
and
dispose
of
it.
g.
When
the
tank
has
cooled,
rinse
it
thoroughly
with
cool
water.
Continue
to
rinse
the
tank
until
the
cleaner
has
been
rinsed
thoroughly
from
the
tank.
h.
Using
a
clean
dry
cloth,
wipe
out
all
of
the
water.
Be
sure
to
completely
remove
all
water,
because
any
residual
water
will
cause
hot
oil
to
splatter
out
of
the
fryer.
CAUTTON
Fryers
with
mild
steel
tanks
must
be
wiped
down
and
coated
with
oil
to
keep
the
tank
from
rusting.
This
must
be
done
if
the
fryer
is
not
going
to
be
used
immediately.
'•
Now
11131
Ae
tank
is
clean,
you
are
ready
to
fill
and
operate
the
fryer.
Refer
to
2.1
for
instructions
on
adding
shortening
to
the
fryer.
1.5.3
Thermostat
Calibration
Check
-
Backup
Thermostat
Only
The
temperature
settings
on
the
thermostat
knob
must
match
the
actual
temperature
in
the
fryer
for
proper
control
of
the
produce
being
cooked.
Fill
the
fryer
with
oil
as
described
in
2.1.
a.
Press
the
START
side
of
the
OFF-ON-START
switch
and
release.
The
switch
will
snap
back
to
the
ON
position.
Allow
the
computer
to
bring
the
fryer
to
normal
operating
temperature.
b.
Let
the
fryer
cycle
4
to
6
times
before
checking
the
temperature.
Open
the
front
door
of
the
fryer
to
gain
access
to
the
backup
thermostat.
c.
Slowly
turn
the
thermostat
knob
and
listen
for
the
thermostat
to
click.
You
can
also
feel
the
thermostat
when
it
clicks.
Although
the
thermostat
is
not
controlling
the
fryer,
its
temperature
probe
is
still
sensing
the
temperature
of
the
fryer.
d.
When
the
thermostat
clicks,
compare
the
setting
on
the
knob
to
the
temperature
reading
of
tire
computer.
If
the
temperature
on
the
thermostat
is
within
5°F
of
the
computer
reading,
the
thermostat
is
calibrated.
If
the
thermostat
dial
is
more
than
5°F
away
from
the
computer
reading,
go
to
step
e.
1-11

Table of Contents

Other manuals for Pitco E7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco E7 and is the answer not in the manual?

Pitco E7 Specifications