Cook
Time
.
The
cooking
time
for
a
product
can
be
changed
to
meet
the
needs
of
any
recipe.
The
time
set
for
a
product
is
the
time
necessary
at
the
SET
temperature
to
cook
the
product.
The
Intellifry
computer
will
compensate
for
any
change
in
the
shortening
temperature
by
increasing
and
decreasing
the
cooking
time.
For
this
reason,
when
a
product
is
cooking
the
time
displayed
is
elastic
time,
not
actual
time.
When
you
put
a
product
in
the
tank
and
start
the
timer,
the
shortening
temperature
will
drop.
The
computer
senses
this
drop
and
extends
the
cook
time
to
ensure
that
the
product
will
receive
the
proper
cooking
time.
Shake
Time
.
An
alarm
will
sound
at
a
preset
time
to
tell
you
to
stir
or
shake
the
product.
DO
NOT
lift
the
product
out
of
the
shortening.
Temperature
.
The
shortening
temperature
for
each
fryer
is
set
separately
and
maintained
by
the
computer.
Only
one
SET
temperature
is
allowed
in
each
computer,
so
products
being
cooked
in
the
left
side
must
be
cooked
at
the
same
temperature
as
the
right
side.
Boil
.
The
Intellifry
computer
has
a
special
boil
mode
program
built
into
it.
This
program
temperature
cannot
be
reset.
The
boil
mode
will
raise
and
hold
the
temperature
of
the
fryer
at
195°F.
To
enter
the
boil
mode
simply
start
the
fryer
as
normal,
the
computer
will
sense
that
the
water
in
the
fry
tank
has
reached
212°F
and
is
not
increasing.
At
this
time
the
computer
will
display
"BOIL"
and
lower
the
temperature
to
195
°F.
The
boil
mode
is
exited
by
turning
the
fryer
ON
when
there
is
oil
in
the
fry
tank.
The
computer
will
sense
that
the
temperature
has
risen
above
212°F
and
continue
to
het
normally.
Boil
mode
is
used
during
weekly
cleaning
of
the
fryer
described
in
the
maintenance
section
of
this
manual.
Computer
or
Probe
Failure
.
If
there
is
a
probe(devise
use
for
sensing
the
temperature
of
the
oil
in
the
fry
tank)
failure
or
a
problem
with
the
computer,
temperature
control
will
automatically
transfer
to
the
auxiliary
thermostat.
The
transfer
is
controlled
by
the
computer
and
a
transfer
relay.
If,
for
any
reason,
the
relay
becomes
de-energized,
temperature
control
will
transfer
to
the
auxiliary
thermostat.
Once
the
problem
has
been
corrected,
(the
computer
senses
that
the
problem
has
been
corrected
or
the
power
is
restored
to
the
transfer
relay)
temperature
control
will
transfer
back
to
the
computer.
2.4.1
Checking
the
Temperature
functions
and
Cooking
times.
To
check
the
ACTUAL
temperature
press
the
once.
To
check
the
SET
temperature
press
the
key
two
times.
After
5
seconds
the
display
will
return
to
normal.
To
check
the
COOK,
SHAKE
and
HOLD
times
press
the
|(X)j
followed
by
the
product
key
you
wish
to
check.
The
times
will
be
displayed
in
sequence
followed
by
a
short
pause,
flnaly
returning
to
the
normal
cook
mode.
When
the
computer
is
calling
for
heat
the
two
lights
in
the
lower
comers
of
the
illuminate.
key
will
2.4.2
Programming
Cook
Time,
Shake
Time
and
Hold
Times.
To
set
the
COOK
time
press
the
npl
key
then
the
(X)
key.
Enter
the
desired
product
key
and
change
2-6

Table of Contents

Other manuals for Pitco E7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco E7 and is the answer not in the manual?

Pitco E7 Specifications

General IconGeneral
BrandPitco
ModelE7
CategoryFryer
LanguageEnglish

Related product manuals