Incorrect Address Position - Adjust Fold Setting
If the address is in the incorrect position when you run a trial piece, refer to these fold settings to help fine
tune the fold setting.
Fold Type Address too High Address too Low
C-fold Decrease Fold A Increase Fold A and increase Fold B by the same amount
Z- fold Increase Fold A Decrease Fold A and increase Fold B by the same amount
Single-fold Increase Fold A Decrease Fold A
Double-fold Decrease Fold A Increase Fold A
It is recommended that the fold is only adjusted by 0.20 inches (5 mm) each time.