EasyManua.ls Logo

Pixsys ATR 142 - Page 48

Pixsys ATR 142
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48 - ATR142 - User manual
53
u.m.c.p.
User Menu Cycle Programmed
Allows the rising/falling gradient and the maintenance
time to be changed from the user menu in pre-program-
med cycle functioning. (parameter 7.7)
di s .
Disabled > Default
ri . G r .
Rising Gradient (modify gradient)
ma.t.i.
Maintenance Time (modify time)
r.G.m.t.
Rising Gradient and Maintenance Time (modify
both)
f a . G r.
Falling Gradient (modify cooling gradient)
r. f .G r.
Rising and Falling Gradient (modify rising and
cooling gradient)
f.G.m.t.
Falling Gradient and Maintenance Time
a LL.
All (modify all parameters for pre-programmed
cyle)
54
vi . tY.
Visualization Type
select visualization for display 1 and 2
1. p.2. s .
1 Process, 2 Setpoint > Default
1. p.2.H.
1 Process, 2 Hide after 3 sec.
1. s .2. p.
1 Setpoint, 2 Process.
1.s.2.H.
1 Setpoint, 2 Hide after 3 sec.
55
d eG r.
Degree
select degree type
c
Celsius > Default
F
Fahrenheit
56
bd . rt.
Baud Rate
select baud rate for serial communication
4.8k
9.6k
19.2k
> Default
28.8k
38.4 k
57.6k

Related product manuals