48 - ATR142 - User manual
53
u.m.c.p.
User Menu Cycle Programmed
Allows the rising/falling gradient and the maintenance
time to be changed from the user menu in pre-program-
med cycle functioning. (parameter 7.7)
di s .
Disabled > Default
ri . G r .
Rising Gradient (modify gradient)
ma.t.i.
Maintenance Time (modify time)
r.G.m.t.
Rising Gradient and Maintenance Time (modify
both)
f a . G r.
Falling Gradient (modify cooling gradient)
r. f .G r.
Rising and Falling Gradient (modify rising and
cooling gradient)
f.G.m.t.
Falling Gradient and Maintenance Time
a LL.
All (modify all parameters for pre-programmed
cyle)
54
vi . tY.
Visualization Type
select visualization for display 1 and 2
1. p.2. s .
1 Process, 2 Setpoint > Default
1. p.2.H.
1 Process, 2 Hide after 3 sec.
1. s .2. p.
1 Setpoint, 2 Process.
1.s.2.H.
1 Setpoint, 2 Hide after 3 sec.
55
d eG r.
Degree
select degree type
c
Celsius > Default
F
Fahrenheit
56
bd . rt.
Baud Rate
select baud rate for serial communication
4.8k
9.6k
19.2k
> Default
28.8k
38.4 k
57.6k