5.1 Schema di collegamento
8
9
10
18
19
20
Q1
8A
230V
1/2HP
Q2
8A
230V
1/2HP
SUPPLY
24...230
Vac/dc
1
2
3
4
5
6
7
11
12
13
14
15
16
17
+24V
SSR
TC
V
mA
AI1
TC
V
mA
TA
AI2
DI
(PnP)
0V
Q3
8A
230V
1/2HP
8
9
10
18
19
20
Q1
8A
230V
1/2HP
Q2
8A
230V
1/2HP
SUPPLY
24...230
Vac/dc
1
2
3
4
5
6
7
11
12
13
14
15
16
17
+24V
SSR
TC
V
mA
AI1
TC
V
mA
TA
AI2
DI
(PnP)
0V
8
9
10
18
19
20
Q1
8A
230V
1/2HP
Q2
8A
230V
1/2HP
SUPPLY
24...230
Vac/dc
1
2
3
4
5
6
7
11
12
13
14
15
16
17
+24V
SSR
TC
V
mA
AI1
TC
V
mA
TA
AI2
Q3
8A
230V
1/2HP
Q4
8A
230V
1/2HP
DI
(PnP)
0V
8
9
10
18
19
20
RS485
Q1
8A
230V
1/2HP
Q2
8A
230V
1/2HP
AO1
V/mA
SUPPLY
24...230
Vac/dc
1
2
3
4
5
6
7
11
12
13
14
15
16
17
+24V
SSR
TC
V
mA
AI1
TC
V
mA
TA
AI2
8
9
10
18
Q1
8A
230V
1/2HP
Q2
8A
230V
1/2HP
AO1
V/mA
SUPPLY
24...230
Vac/dc
1
2
3
4
5
6
7
11
12
13
14
15
16
17
+24V
SSR
TC
V
mA
AI1
TC
V
mA
TA
AI2
19
20
DI
(PnP)
0V
ATR401-22ABC ATR401-23ABC ATR401-24ABC ATR401-22ABC-T ATR401-22ABC-D
Alimentazione
SUPPLY
24...230
Vac/dc
1
2
JP4
TS1
C21
Alimentazione switching a range esteso 2 selezioni:
24 Vac/dc ±15% con inserzione Jumper JP4;
115…230 Vac/dc ±15% senza Jumper JP4;
50/60 Hz – 5,5 VA (con isolamento galvanico).
Ingresso analogico AI1
11
12
AI1
TC
Shield/Schermo
Per termocoppie K, S, R, J.
Rispettare la polarità.
Per eventuali prolunghe utilizzare cavo
compensato e morsetti adatti alla termocoppia
utilizzata (compensati).
Quando si usa cavo schermato, lo schermo deve
essere collegato a terra ad una sola estremità.