18 ATR 621 - User manual
Press Display Do
7
O
K
Red display shows

. Green
display shows the step setpoint
(temperature that has to be
reached within given time).
With keys or enter
setpoint (temperature reached
at step end).
6.1.3
Programming of the auxiliary output (if con gured)
Press Display Do
8
O
K
Red display shows  . Green
display shows  o  .
If  is not programmed as
auxiliary time ( ) skip to
point 10.
9
Set auxiliary output status du-
ring the step:  for active
output and  for not active
output.
10
O
K
If ,  are programmed as time auxiliary go back to point
9. Green display will visualize the number and the status of the
selected auxiliary ( /  ,  /  ). Once selected
all auxiliary go back to point 5.
6.1.4 End programming
Press Display Do
11
O
K
Controller returns in STOP
mode saving the cycle. Red
display shows .
If
, ,  are selected
as auxiliary ( ) repeat the
procedure of points 9 and 10
for the output status at cycle
end.
7 Cycle start
7.1 Start of a cycle and setting of delayed start
Red display shows .
Press Display Do
1
STA
R
T
STO
P
Red display shows cycle
selection.

Table of Contents